This view offers a dedicated tool for the conversion of DCE MR image signal intensities to contrast agent (CA) concentration. It contains a subset of the conversion tools for T1-weighted signal intensities, which are a part of the DCE MR Perfusion Datafit View (see Signal to concentration conversion settings). Additionally, it allows for the conversion between T2-weighted MR signal intensities and contrast agent concentration.
If you have any questions, need support, find a bug or have a feature request, feel free to contact us at www.mitk.org.
The view offers the choice between a 3D Image and a 4D image. If a 4D image is selected, the Selected Time Series needs to be specified. In this case, the baseline image is automatically extracted as the first time point image of the time series. In case of a 3D image to be converted, additionally to the selected 3D image a Baseline Image (without CA) has to be specified.
In the configuration section, the following types of conversion can be chosen:
The contrast agent concentration c is calculated according to the formula: c = -k/TE*ln(S(t)/S(0)), where S(t) is the dynamic T2-weighted signal intensity, S(0) the baseline signal, k a user-defined conversion factor and TE the echo time of the employed sequence. In practice, the factor k is often set to unity.